Mechanics of flow

Principle

The Doppler effect is used with ultrasonic waves to investigate the laws of stationary laminar flow, which underlie a great many technical applications. The liquid under investigation flows through a circuit of tubing. Particular aspects to be studied experimentally ...

 
Détails

Numéro d´article: P5140100

Level measurement

Principle
For the experiment, a level measuring system for a two-phase liquid tank is set up and a calibration curve for the filling volumes is recorded. One task is to determine the minimum measurement volume ("dead band"). For maximum tank filling, an ultrasoni ...

 
Détails

Numéro d´article: P5141100

Flow MeasurementUltrasonic Doppler effect

 
Détails

Numéro d´article: P5142100

Vitesse des ultrasons dans un matériau solide

Principe de l'expérience:

Détermination de la vitesse du son de l'acrylique par technique de temps de vol (time of flight) avec un échoscope à ultrasons. Les mesures par méthode de réflexion sont effectuées sur trois cylindres de longueur différe ...

 
Détails

Numéro d´article: P5160100

Echographie ultrasonique - SCAN A

Principe de l'expérience

Une onde ultrasonique tranversant un échantillon solide sera renvoyée par des discontinuités (défauts, fissures). La relation entre temps de vol et vitesse du son de l'onde renvoyée permet de calculer la distance entre la sonde et la di ...

 
Détails

Numéro d´article: P5160200

Echographie ultrasonique - SCAN B

Principe de l'expérience:

Introduction aux aspects fondamentaux des techniques du B-scan ultrasonique en utilisant un échoscope sur un objet de test simple. Discussion de la qualité d'image en termes de résolution spatiale, focalisation ultrasonique, aberration ...

 
Détails

Numéro d´article: P5160300

Mesure de l'angle du faisceau

Principe de l'expérience

L'expérience démontre l'application des palpeurs à incidence oblique en contrôle non-destructif. On observe les échos d'ondes transversales et longitudinales provenant d'un bloc de test en aluminium suivant trois angles de lig ...

 
Détails

Numéro d´article: P5160400

Diffraction des temps de vol (TOFD)

Principe de l'expérience

La profondeur de fissure dans un bloc de test en aluminium avec sept fissures de profondeurs différentes (coupes de scie) est déterminée par deux méthodes. Les fissures dans le matériau sont examinées avec un palpeur à incidence ob ...

 
Détails

Numéro d´article: P5160500

Détection de discontinuités

Principle

Various ultrasonic locating techniques are used on a test body with a variety of differing discontinuities. The body is first tested by scanning through it and an investigation is made to determine which techniques are best for detecting which types of faults. After ...

 
Détails

Numéro d´article: P5160600

Dépendance en fréquence du pouvoir de résolution

Principle

An echoscope is used to measure two neighbouring faults in order to determine the differing axial resolutions of a 1-MHz and a 4-MHz ultrasonic probe. This will illustrate the relationships between wavelength, frequency, pulse length and resolution.

 

 
Détails

Numéro d´article: P5160700

Atténuation des ultrasons dans les matériaux solides

Principle

The attenuation of ultrasound in solid bodies (polyacrylic) is measured at three different frequencies using a reflection method and by scanning through the bodies with an echoscope. The results give an indication of how attenuation depends on frequency.

 
Détails

Numéro d´article: P5160800

Ondes de cisaillement dans les matériaux solides

Principle

An echoscope is used to measure the emergence of longitudinal and transverse waves when sound passes through flat rectangular blocks made of differing materials. The relationship between amplitude and angle can be used to determine the speed of sound in the blocks i ...

 
Détails

Numéro d´article: P5160900

Détermination de la zone focus

Principle

A hydrophone is used to measure the amplitude of the sound pressure from an ultrasound probe along the axis of the sound transmission. The amplitude distribution is then used to find the length of the near field. In addition, the sound amplitude is measured at ...

 
Détails

Numéro d´article: P5161000

Méthode de scan mécanique

Principle

A computer-controlled scanner is used to make a B scan of a test body using two probes of different frequency (1 MHz and 2 MHz) and various locating resolutions. A comparison is then made between the effects on the resolution capabilities.

 
Détails

Numéro d´article: P5161100

Tomodensimètrie à ultrasons assistée par PC

Principle

First an explanation of image generation using the CT algorithm is given. An attenuation and sound speed tomogram is then made on a simple test object and any differences are then discussed.

 
Détails

Numéro d´article: P5161200